| Pinnacle Systems, Inc. - Safety Light Curtains, Safety Mat Systems and Ergonomic Palm Buttons |
| Page: HUB Ordering Procedure |
Universal Safety Controller HUB™
Multiple Safety Devices...One Safety Controller!
Ordering Procedure
Ordering/Pricing Procedure
Format Model#: SH-XX(YY)-XX(YY)-XX(YY)- …
(where XX is the Input device type, where YY is an OPTIONAL Output
device type)
Example Model#: SH-2-2-6-10-2-2D-6D-8C
(2 light curtains + 1 ESTOP tied to C with latching RESET, 1 light curtain + mat tied to C with no latching,1 light curtain + 1 ESTOP tied to D with no latching)
Current List of Input Device Types
|
XX |
Terminals used |
Input Device Type |
|
1(T) |
2 |
START or STOP or CANCEL button inputs |
|
2 |
2 |
CAT 4 Light curtain or CAT 2 ESTOP |
|
3 |
2 |
Foot Pedal |
|
4 |
3 |
Cat 3 ESTOP input |
|
5 |
|
Reserved |
|
6 |
4 |
Cat 4 ESTOP input |
|
7(T) |
2 |
Palm button station (2 palm buttons) N.O. from each button |
|
8 |
4 |
NSD Safety Mat or any 4-wire pressure sensor device |
|
9(T) |
2 |
Limit Switch (mechanical or Pressure) |
|
10(T) |
2 |
Reset Button for Channel C |
|
11(T) |
2 |
Reset Button for Channel D |
|
12(T) |
2 |
Cincinnati Interface for Channel C |
|
13(T) |
2 |
Cincinnati Interface for Channel D |
|
14(T) |
2 |
Mute-Out bypass for Channel C |
|
15(T) |
2 |
Mute-Out bypass for Channel D |
|
16(T) |
2 |
EDM (External Device Monitor) for Channel C |
|
17(T) |
2 |
EDM (External Device Monitor) for Channel D |
|
18 |
|
Reserved |
|
19 |
|
Reserved |
|
20(T) |
2 |
Key Switch bypass (used to bypass other devices) |
|
21(T) |
2 |
Prox sensor input (1/4” pinch point) |
|
22(T) |
2 |
Mute-Out bypass for Foot Switch device #3 |
|
23(T) |
4 |
Palm button station (2 palm buttons) N.O. and N.C. from each button |
Current List of Output Device Types
|
YY |
Channel output |
Output Device Type |
|
|
C |
Assume Devices use Channel C if left blank Assume Device Status tied to each Channel E output |
|
E |
E |
Device Status Output (default) |
|
C |
C |
Devices tie to Channel C mechanical relays |
|
D |
D |
Devices tie to Channel D solid state relays |
|
|
|
|
|
240C |
C |
Timer function to hold Channel C ON |
|
241C |
C |
Timer function to hold Channel C OFF |
|
242D |
D |
Timer function to hold Channel D ON |
|
243D |
D |
Timer function to hold Channel D OFF |
|
251CD |
C/D |
Devices Latch C ON and D OFF |
|
252CD |
C/D |
Devices Latch D ON and C OFF |
|
253CD |
C/D |
Devices Latch both C & D OFF |
|
254CD |
C/D |
ESTOP devices turn C & D OFF both |
|
255CD |
C/D |
Devices turn C & D OFF both |
Email: hub@pinnaclesystems.com
Call: (800) 569-7697
Fax: (412) 262-4055
Contacting us via the information above will initiate the next steps for your total safety solution.