Model DR
DIN-rail Controller and Light
Curtain
Smart Controller
|
Unique Features
|
The Smart DIN-Rail Controller makes machine guarding safer, easier to use and will enhance machine utilization measurably. It is unique in the machine guarding industry for the ability to constantly display the operating conditions of the safety light curtain. The Controller informs the user of any faults, failures and the current operating status of the safety system in plain English on the external message display center. The message display is located on the front panel of the Controller. This gives the machine operator and front line supervisors access to information quickly and safely.
The DIN-Rail Controller diagnostic message display will provide all faults related to redundant circuitry, microprocessors, captive contact safety relays, bad grounds, external infrared sources, shorts, blanking functions, etc. The Controller will also display on the message center the locations of misaligned or obstructed beams and then count and display how many beams have been obstructed. Additionally, if a printed circuit board or component should fail, the faulty board and beam number will be shown on the display. The board then can be replaced quickly in the field, eliminating costly downtime.
The counting and displaying the number of beams blanked out is required information when determining the depth penetration factor for proper installation of any light curtain.
ANSI B11.19-1990.
These standard provisions are designed into the DIN-Rail Controller Module to facilitate any guarding system interface and monitoring desired. Usage is optional.
CINCINNATI INTERFACE - with Red LED Indicator
or Emergency Stop Input (optional)
Description: This is provided to allow an external device to determine if the light curtain is still capable of
shutting down the safety control circuit. The Cincinnati Interface allows an external device to override the light
curtain and initiate a RED condition and open up the standard output relay contacts.
Application: Cincinnati Press, PLC
EXTERNAL RELAY CHECK- with
Green LED Indicator
Description: The Pinnacle External Relay Check allows the MicroGuard® to monitor a pair of external relays in
series using the external relays secondary set of DRY contacts, provided that they are N.C. force-guided contacts.
The captive or force-guided contacts will maintain the identical position as the primary set of contacts on the
external relays, except that the secondary set of contacts are wired up to signal the reverse of the primary.
(i.e., primary are N.O., secondary are N.C.). The circuit looks for both closing and opening of the external relay
contacts. The Microguard® system is a safe external relay check.
Application: Monitoring external relay contacts for shorts or opens.
EXTERNAL VOLTAGE CHECK
PROVISION - with Green LED Indicator
Description: The External Voltage Check allows for the MicroGuard to monitor voltage coming from any outside source
as a condition for keeping the light curtain GREEN. This option is very similar to the External Relay Check, except
that this operates with high voltage so that it can be used to monitor other devices besides relay contacts.
Application: Monitor voltage at a solenoid, relay, etc.
AUXILIARY OUTPUT CONTACT
PROVISIONS
Description: The Auxiliary Output Contact option provides both a N.O. and N.C. isolated (DRY) contact output to
signal the condition of the light curtain. The output is used in conjunction with the standard pair of output
relays that are wired to the safety circuit of the equipment.
Application: Signal to PLC, etc.
DATA INPUT/OUTPUT FOR USE WITH REMOTE PLC
OPTION
Description: This option allows the user to specify up to four signal lines as either input and/or output lines for
issuing remote commands to the MicroGuard® and/or sending commands to a PLC.
Application: Use this option if you need to know object size, or to use your PLC to program Auto-Blank,
Floating-Blank, reset "Penetration," adjust guarded area, etc. This option is programmed at the factory for the
user and is custom.
Output Circuitry
|
||
WARNING - Both safety relays in the
dual stop configuration must be wired into the machine isolated stop circuits of the
machine control.
|