Pinnacle Systems, Inc. - Safety Light Curtains, Safety Mat Systems and Ergonomic Palm Buttons |
Page: Model PPG Ordering Procedure |
Model PPG
Perimeter Guarding
Ordering
Procedure
Example Part # |
PPG |
36 |
3.0 |
45 |
(Options) |
|
PPG Prefix
|
Scanning Height |
Beam Spacing |
Scanning Distance |
|
1. Specify
scanning height of unit--Pylon Sizes (Protected
Area)
Inches: 24,
30, 36, 48, 60, 72, 84, 96
Millimeters: 609.6, 762, 914.4,
1219.2, 1524, 1828.8, 2133.6, 2438.4
2. Specify
beam spacing--Beam Spacing
1.5 - 1.5”
(38.1mm) Spacing of Beams
3.0 - 3.0” (76.2mm) Spacing of
Beams
6.0 - 6.0” (152.4mm) Spacing of
Beams
12.0 - 12.0” (304.8mm) Spacing of
Beams
3. Specify scanning distance — 90’ (27m) maximum
Options
Auxiliary
Output Contact. Provides an
isolated (dry) contact output to be used as a signal
line. Specify N.O. or N.C. output. Add suffix AO to light
curtain Model Number.
External Relay Check. This option monitors the control relays of the guarded machine to assure that the machine control relays change state when the safety light curtain sends a stop signal. Add suffix ER to light curtain Model Number.
24VDC Power Source. Add suffix DC to light curtain Model Number.