Pinnacle Systems, Inc. - Safety Light Curtains, Safety Mat Systems and Ergonomic Palm Buttons |
Page: HUB Terminal Quadrants |
Universal Safety Controller HUBâ„¢
Multiple Safety Devices...One Safety Controller!
Terminal Quadrants
Upper Left - 12 Position Connector
12 Position Connector |
CAN Network /Solid State Status Outputs / Solid State Safety Outputs |
Terminal 29 |
CAN L (Slave) Expansion HUB |
Terminal 30 |
CAN H (Slave) Expansion HUB |
Terminal 31 |
Status Output E-1 (1/2A Solid State, +24V or GND out) |
Terminal 32 |
Status Output E-2 (1/2A Solid State, +24V or GND out) |
Terminal 33 |
Status Output E-3 (1/2A Solid State, +24V or GND out) |
Terminal 34 |
Status Output E-4 (1/2A Solid State, +24V or GND out) |
Terminal 35 |
Status Output E-5 (1/2A Solid State, +24V or GND out) |
Terminal 36 |
Status Output E-6 (1/2A Solid State, +24V or GND out) |
Terminal 37 |
Status Output E-7 (1/2A Solid State, +24V or GND out) |
Terminal 38 |
Status Output E-8 (1/2A Solid State, +24V or GND out) |
Terminal 39 |
D-1 Safety Output (1/2A Solid State Safety Output) Monitored * |
Terminal 40 |
D-2 Safety Output (1/2A Solid State Safety Output) Monitored * |
*Must be wired to control reliable systems or our 52-278 captive contact safety relays. Higher Amp Output for Channel D also available.
Lower Left - 16 Position Connector
16 Position
Connector |
Power Input / Safety Relay Output / Auxiliary Relay |
Terminal 1 |
Power Supply Input (+24vdc input) |
Terminal 2 |
Power Supply Input (ground) |
Terminal 3 |
Earth Ground |
Terminal 4 |
C-1a Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored |
Terminal 5 |
C-1b Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored |
Terminal 6 |
C-2a Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored |
Terminal 7 |
C-2b Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored |
Terminal 8 |
C-3a Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored |
Terminal 9 |
C-3b Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored |
Terminal 10 |
C-4a Auxiliary Output (N.O.) 5A@250vac (Dry) |
Terminal 11 |
C-4b Auxiliary Output (C) 5A@250vac (Dry) |
Terminal 12 |
C-4c Auxiliary Output (N.C.) 5A@250vac (Dry) |
Terminal 13 |
Open |
Terminal 14 |
Open |
Terminal 15 |
+24vdc out (feed thru from Terminal #1) |
Terminal 16 |
Ground out (feed thru from Terminal #2) |
Upper Right - 12 Position Connector
12 Position
Connector |
Channel B / Safety or non-safety inputs B-1 to B-12 |
Terminal 41 |
Channel B-1 (pnp/npn input or signal output) |
Terminal 42 |
Channel B-2 (pnp/npn input or signal output) |
Terminal 43 |
Channel B-3 (pnp/npn input or signal output) |
Terminal 44 |
Channel B-4 (pnp/npn input or signal output) |
Terminal 45 |
Channel B-5 (pnp/npn input or signal output) |
Terminal 46 |
Channel B-6 (pnp/npn input or signal output) |
Terminal 47 |
Channel B-7 (pnp/npn input or signal output) |
Terminal 48 |
Channel B-8 (pnp/npn input or signal output) |
Terminal 49 |
Channel B-9 (pnp/npn input or signal output) |
Terminal 50 |
Channel B-10 (pnp/npn input or signal output) |
Terminal 51 |
Channel B-11 (Mat + IN) (pnp/npn input or signal output) Dedicated terminals 11 & 12 for |
Terminal 52 |
Channel B-12 (Mat - IN) (pnp/npn input or signal output) powering control logic for Safety Mats, Edges and Bumpers. |
Lower Right - 12 Position Connector
12 Position
Connector |
Channel A / Safety or non-safety inputs A-1 to A-12 |
Terminal 17 |
Channel A-1 (pnp/npn input or signal output) |
Terminal 18 |
Channel A-2 (pnp/npn input or signal output) |
Terminal 19 |
Channel A-3 (pnp/npn input or signal output) |
Terminal 20 |
Channel A-4 (pnp/npn input or signal output) |
Terminal 21 |
Channel A-5 (pnp/npn input or signal output) |
Terminal 22 |
Channel A-6 (pnp/npn input or signal output) |
Terminal 23 |
Channel A-7 (pnp/npn input or signal output) |
Terminal 24 |
Channel A-8 (pnp/npn input or signal output) |
Terminal 25 |
Channel A-9 (pnp/npn input or signal output) |
Terminal 26 |
Channel A-10 (pnp/npn input or signal output) |
Terminal 27 |
Channel A-11 (Mat + OUT) (pnp/npn input or signal output) Dedicated terminals 11 & 12 for |
Terminal 28 |
Channel A-12 (Mat - OUT) (pnp/npn input or signal output) powering control logic for Safety Mats, Edges and Bumpers. |
View of HUB