SSSR Safety
Relay Interface
Part #SSSR
Allows customer selectable Manual or Auto Reset. Fits in a smaller space than two
52-278 Safety Relays.
Basic device for Emergency-Stop and Safety Gate Applications
• Basic device to EN 60204-1:2005 and EN ISO 13849:2007 for single
or dual E-stop monitoring.
• PL e /
category 4 in accordance with EN ISO 13849-1:2007 (previously EN 954:1997 category
4)
• SILCL 3 in accordance with EN
62061:2005
• Stop category 0 acc. EN
60204-1
• Manual or automatic
start
• Cross
monitoring
• Feedback loop to monitoring
external contactors
• 2 Enabling paths, 1
signalling path
• Processing of signals
from output switching devices (OSSD) of light curtains acc. EN 61496-1.
• To connect to load side of safety mats acc. EN
1760-1
• Debouncing of
inputs
Description of Device and Function
SSSR - This device is a two-channel safety switching device for emergency stop applications with self-monitoring on each ON-OFF cycle. It conforms to EN 60204-1 and is equipped with positively driven relays.