Universal Safety Controller HUB™
Multiple Safety Devices...One Safety Controller!
Options

HUB

Options (Add underlined as suffix to part number)

Mute-out (MO) – Mutes out a safety light curtain device during the non-hazardous portion of the machine cycle. Requires one safety input.

MOC - Mute out the signal routed thru safety output C

MOD - Mute out the signal routed thru safety output D

MOB - Mute out the signal routed thru safety output C and D

Amber Anmuting light (indicator) output can also be supplied

External Device Monitoring – (EDM) – Method in which the Safety Controller HUB monitors the state of various external control devices in a control reliable manner. EDM requires the use of two safety inputs.

EDMC - External Device Monitoring routed thru safety output C

EDMD - External Device Monitoring routed thru safety output D

EDMB - External Device Monitoring routed thru safety output C and D

Two Hand Control – (2H) – Provides anti-tie down/concurrent operation logic for operator two hand controls for machine actuation. Requires one safety input.

2HD - The two-hand control option is routed thru safety output D.

Cincinnati interface – (CI) – Requires the Safety Controller HUB to issue a stop command on every machine cycle. Requires one safety input.

CIC - Cincinnati Interface signal routed thru safety output C

CID - Cincinnati Interface signal routed thru safety output D

CIB - Cincinnati Interface signal routed thru safety output C and D

Latching Relay – (LR) – Resettable latching relays option requires that the individual safety device be manually reset after every time the device signals a stop. (The latching relay option does not occupy a safety input.) Reset requires remote manual reset button.

LRC - Latching relay signal routed thru safety output C

LRD - Latching relay signal routed thru safety output D

LRB - Latching relay signal routed thru safety output C and D

Expansion Module – (EXP) – Doubles the safety HUB inputs & outputs. The modules are interconnected via the two wire CAN network connections on each module.

Ethernet – (ET) – Capability provides the ability to program or review status of the Safety HUB via the Internet.

The complete system can be upgraded or changed in the field for any system changes that may occur. Pinnacle Systems will configure the Safety HUB to meet your specific requirements.

 