Ordering
Procedure
Mat
Controller Example Part
# A - 1 - 7 - 2 - 7
A
|
1
|
7
|
2
|
7
|
A-Metal Box
Controller. Mat Control and
Message Display mounted in stand alone NEMA
12 lockable enclosure.
B-Board only system
supplied on a mounting back
plate. Mat controller boards and
message display to be installed into an
existing control panel.
|
Mat Controller input power
1-110 VAC
2-220 VAC
3-24 VDC (24 VDC must be used for European Projects
"CE") |
Number of individual mats
(inputs) to be wired back to STTS Mat
Controller.
Specify quantity:
1 to 8 |
Number of isolated control zone
(outputs) desired.
1- 1 Zone
2 - 2 Zones
3 - 3 Zones
4 - 4 Zones (requires larger control box),
etc. |
Optional mat plug receptacles
mounted on the STTS Mat Controller.
Receptacles require mats with wiring style
"R."
Specify quantity: 1-8 |
D-DIN-rail
Controller
|
3
(24 VDC input power only)
|
1 to 4
|
1
(1 zone output only)
|
RSD
(Remote Status Display, optional)
|
Mat Assembly
Example Part # N - Y - 60 - 96 - P - 20 -
S
N
|
Y
|
60
|
96
|
P
|
20
|
S
|
Mat
Style |
Mat Color
|
Mat Width
Dimension
"A"
|
Mat Length
Dimension
"B"
|
Mat Wiring Style
|
Mat Wire* Length
|
Specials
(Optional)
|
R-Ribbed Surface
N-Non-Skid Surface
H-High Temp Surface
(Excellent for weld splatter, molten plastic, die
casting, forging operations, and wet
environments) |
B-Black
Y-Yellow |
12, 18, 24, 30, 36, 42, 48, 54,
60, 66, 72 |
12, 18, 24, 30, 36, 42, 48, 54,
60, 66, 72, 78, 84, 90, 96, 102, 108, 114,
120, 126, 132, 138, 144 |
W-Hard wire lead from mat to mat
controller.
P-Plug connector at mat with hard
wire lead to mat controller
R-Plug connector at mat with plug
extension to mat controller receptacle (requires
plug receptacle on mat controller) |
W-For wire leads. Order in feet;
20’ feet supplied standard. Specify longer
lengths if needed; 100’ maximum.
P-For plug connector mat with hard
wire lead to mat controller. Order in feet; 20’
supplied standard. Extension lengths available:
10’, 15’, 20’, 25’, 50’.
R-Select plug extension length in
feet. Lengths available include 10’, 15’, 20’,
25’. |
S-Designates a
special size, cut, contour, hole, notch, angle
or wire exit location in the mat. Please submit
drawing. |
EXAMPLE — Part #
N-Y-60-96-P-20 is a non-skid surface yellow mat 60” wide
and 96” long with a plug connector. The plug extension is
20’ long and will terminate at the mat control box. Plug
receptacle mounted on control panel optional. Refer to
mat controller ordering procedure
section.
*MAT
WIRING —
Individual mat homerun wiring or plug extensions back to
the control box are required for easing installation and
diagnostics for maintenance troubleshooting. This will
eliminate cumbersome “daisy chain” wiring practices of
mat systems. It also eliminates numerous wiring
connection points buried under the perimeter trim which
are time intensive to troubleshoot.
SPECIALS...The
CustomatTM series
The ultimate customized mat
system in the industry. Also available with the smart
“Intelligent Matting™” capability. This series can provide
customized mats, machine inlays, customized activation
thresholds, wire exits, etc. Submit drawing and requirements to
factory.
|